Fossil fuel power station




Facility that burns fossil fuels to produce electricity









The 5,400 MW Bełchatów Power Station in Poland – one of the world's largest coal-fired power stations.




















2016 World [civil] power generation by source [IEA, 2018] (Percentages of 24.973 TWh)[1]



  Coal (38.4%)


  Natural Gas (23.2%)


  Hydro (16.3%)


  Nuclear fission (10.4%)


  Oil (3.7%)


  Non hydro renew. (8%)



A fossil fuel power station is a thermal power station which burns a fossil fuel such as coal, natural gas, or petroleum to produce electricity. Central station fossil fuel power plants are designed on a large scale for continuous operation. In many countries, such plants provide most of the electrical energy used. Fossil fuel power stations have machinery to convert the heat energy of combustion into mechanical energy, which then operates an electrical generator. The prime mover may be a steam turbine, a gas turbine or, in small plants, a reciprocating internal combustion engine. All plants use the energy extracted from expanding gas, either steam or combustion gases.
Although different energy conversion methods exist, all thermal power station conversion methods have efficiency limited by the Carnot efficiency and therefore produce waste heat.


By-products of fossil fuel power plant operation must be considered in their design and operation. The flue gas from combustion of the fossil fuels is discharged to the air. This gas contains carbon dioxide and water vapor, as well as other substances such as nitrogen oxides (NOx), sulfur oxides (SOx), mercury, traces of other metals, and, for coal-fired plants, fly ash. Solid waste ash from coal-fired boilers must also be removed. Some coal ash can be recycled for building materials.[2]


Fossil fueled power stations are major emitters of carbon dioxide (CO2), a greenhouse gas which is a major contributor to global warming.
The results of a recent study[3] show that the net income available to shareholders of large companies could see a significant reduction from the greenhouse gas emissions liability related to only natural disasters in the United States from a single coal-fired power plant.
However, as of 2015, no such cases have awarded damages in the United States.
Per unit of electric energy, brown coal emits nearly two times as much CO2 as natural gas, and black coal emits somewhat less than brown.
Carbon capture and storage of emissions has been proposed to limit the environmental impact of fossil fuel power stations, but it is still at a demonstration stage.




Contents






  • 1 Basic concepts: heat into mechanical energy


  • 2 Plant types


    • 2.1 Steam


    • 2.2 Gas turbine and combined gas/steam


    • 2.3 Reciprocating engines




  • 3 Fuels


    • 3.1 Coal


      • 3.1.1 Transport and delivery


      • 3.1.2 Fuel processing




    • 3.2 Natural gas


      • 3.2.1 Dash for gas




    • 3.3 Oil




  • 4 Combined heat and power


  • 5 Environmental impacts


    • 5.1 Carbon dioxide


      • 5.1.1 Estimation of carbon dioxide emissions




    • 5.2 Particulate matter


    • 5.3 Wastewater


    • 5.4 Radioactive trace elements


    • 5.5 Water and air contamination by coal ash


      • 5.5.1 Mercury contamination






  • 6 Greening of fossil fuel power plants


    • 6.1 Coal Pollution Mitigation


    • 6.2 Clean gas




  • 7 Alternatives to fossil fuel power plants


    • 7.1 Relative cost by generation source




  • 8 See also


  • 9 References


  • 10 Bibliography


  • 11 External links





Basic concepts: heat into mechanical energy



In a fossil fuel power plant the chemical energy stored in fossil fuels such as coal, fuel oil, natural gas or oil shale and oxygen of the air is converted successively into thermal energy, mechanical energy and, finally, electrical energy. Each fossil fuel power plant is a complex, custom-designed system. Construction costs, as of 2004[update], run to US$1,300 per kilowatt, or $650 million for a 500 MWe unit.[citation needed] Multiple generating units may be built at a single site for more efficient use of land, natural resources and labor. Most thermal power stations in the world use fossil fuel, outnumbering nuclear, geothermal, biomass, or solar thermal plants.


The second law of thermodynamics states that any closed-loop cycle can only convert a fraction of the heat produced during combustion into mechanical work. The rest of the heat, called waste heat, must be released into a cooler environment during the return portion of the cycle. The fraction of heat released into a cooler medium must be equal or larger than the ratio of absolute temperatures of the cooling system (environment) and the heat source (combustion furnace). Raising the furnace temperature improves the efficiency but complicates the design, primarily by the selection of alloys used for construction, making the furnace more expensive. The waste heat cannot be converted into mechanical energy without an even cooler cooling system. However, it may be used in cogeneration plants to heat buildings, produce hot water, or to heat materials on an industrial scale, such as in some oil refineries, plants, and chemical synthesis plants.


Typical thermal efficiency for utility-scale electrical generators is around 37% for coal and oil-fired plants[4], and 56 – 60% (LEV) for combined-cycle gas-fired plants. Plants designed to achieve peak efficiency while operating at capacity will be less efficient when operating off-design (i.e. temperatures too low.)[5]


Practical fossil fuels stations operating as heat engines cannot exceed the Carnot cycle limit for conversion of heat energy into useful work. Fuel cells do not have the same thermodynamic limits as they are not heat engines.


The efficiency of a fossil fuel plant may be expressed as its heat rate, expressed in BTU/kilowatthour or megajoules/kilowatthour.



Plant types




Steam


In a steam turbine power plant, fuel is burned in a furnace and the hot gasses flow through a boiler. Water is converted to steam in the boiler; additional heating stages may be included to superheat the steam. The hot steam is sent through controlling valves to a turbine. As the steam expands and cools, its energy is transferred to the turbine blades which turn a generator. The spent steam has very low pressure and energy content; this water vapor is fed through a condenser, which removes heat from the steam . The condensed water is then pumped into the boiler to repeat the cycle.


Emissions from the boiler include carbon dioxide, oxides of sulfur, and fly ash from non-combustible substances in the fuel. Waste heat from the condenser is transferred either to the air, or sometimes to a cooling pond, lake or river.



Gas turbine and combined gas/steam




480 megawatt GE H series power generation gas turbine




Currant Creek Power Plant near Mona, Utah is a natural gas fired electrical plant.


One type of fossil fuel power plant uses a gas turbine in conjunction with a heat recovery steam generator (HRSG). It is referred to as a combined cycle power plant because it combines the Brayton cycle of the gas turbine with the Rankine cycle of the HRSG. The thermal efficiency of these plants has reached a record heat rate of 5690 Btu/(kW·h), or just under 60%, at a facility in Baglan Bay, Wales.[6]


The turbines are fueled either with natural gas, syngas or fuel oil. While more efficient and faster to construct (a 1,000 MW plant may be completed in as little as 18 months from start of construction), the economics of such plants is heavily influenced by the volatile cost of fuel, normally natural gas. The combined cycle plants are designed in a variety of configurations composed of the number of gas turbines followed by the steam turbine. For example, a 3-1 combined cycle facility has three gas turbines tied to one steam turbine. The configurations range from (1-1), (2-1), (3-1), (4-1), (5-1), to (6-1)[citation needed]


Simple-cycle or open cycle gas turbine plants, without a steam cycle, are sometimes installed as emergency or peaking capacity; their thermal efficiency is much lower. The high running cost per hour is offset by the low capital cost and the intention to run such units only a few hundred hours per year. Other gas turbine plants are installed in stages, with an open cycle gas turbine the first stage and additional turbines or conversion to a closed cycle part of future project plans.



Reciprocating engines


Diesel engine generator sets are often used for prime power in communities not connected to a widespread power grid. Emergency (standby) power systems may use reciprocating internal combustion engines operated by fuel oil or natural gas. Standby generators may serve as emergency power for a factory or data center, or may also be operated in parallel with the local utility system to reduce peak power demand charge from the utility. Diesel engines can produce strong torque at relatively low rotational speeds, which is generally desirable when driving an alternator, but diesel fuel in long-term storage can be subject to problems resulting from water accumulation and chemical decomposition. Rarely used generator sets may correspondingly be installed as natural gas or LPG to minimize the fuel system maintenance requirements.


Spark-ignition internal combustion engines operating on gasoline (petrol), propane, or LPG are commonly used as portable temporary power sources for construction work, emergency power, or recreational uses.


Reciprocating external combustion engines such as the Stirling engine can be run on a variety of fossil fuels, as well as renewable fuels or industrial waste heat. Installations of Stirling engines for power production are relatively uncommon.


Historically, the first central stations used reciprocating steam engines to drive generators. As the size of the electrical load to be served grew, reciprocating units became too large and cumbersome to install economically. The steam turbine rapidly displaced all reciprocating engines in central station service.



Fuels



Coal




Diagram of a typical steam-cycle coal power plant (proceeding from left to right)



Coal is the most abundant fossil fuel on the planet, and widely used as the source of energy in thermal power stations. It is a relatively cheap fuel, with some of the largest deposits in regions that are stable politically, such as China, India and the United States. This contrasts with natural gas, the largest deposits of which are located in Russia, Iran, Qatar, Turkmenistan and the US. Solid coal cannot directly replace natural gas or petroleum in most applications, petroleum is mostly used for transportation and the natural gas not used for electricity generation is used for space, water and industrial heating. Coal can be converted to gas or liquid fuel, but the efficiencies and economics of such processes can make them unfeasible.[citation needed] Vehicles or heaters may require modification to use coal-derived fuels. Coal is an impure fuel and produces more greenhouse gas and pollution than an equivalent amount of petroleum or natural gas. For instance, the operation of a 1000-MWe coal-fired power plant results in a nuclear radiation dose of 490 person-rem/year, compared to 136 person-rem/year, for an equivalent nuclear power plant including uranium mining, reactor operation and waste disposal.[7]


As of 2009[update] the largest coal-fired power station is Taichung Power Plant in Taiwan. The world's most energy-efficient coal-fired power plant is the Avedøre Power Station in Denmark.[8]



Transport and delivery




Coal-fired power plants provide about 32 percent of consumed electricity in the United States, As of September 2017.[9] This is the Castle Gate Plant near Helper, Utah.


Coal is delivered by highway truck, rail, barge, collier ship or coal slurry pipeline. Some plants are even built near coal mines and coal is delivered by conveyors. A large coal train called a "unit train" may be 2 kilometres (1.2 mi) long, containing 130-140 cars with around 100 tonnes (98 long tons; 110 short tons) of coal in each one, for a total load of over 10,000 tonnes (9,800 long tons; 11,000 short tons). A large plant under full load requires at least one coal delivery this size every day. Plants may get as many as three to five trains a day, especially in "peak season" during the hottest summer or coldest winter months (depending on local climate) when power consumption is high. A large thermal power plant such as the now decommissioned Nanticoke, Ontario stores several million metric tons of coal for winter use when the lakes are frozen.


Modern unloaders use rotary dump devices, which eliminate problems with coal freezing in bottom dump cars. The unloader includes a train positioner arm that pulls the entire train to position each car over a coal hopper. The dumper clamps an individual car against a platform that swivels the car upside down to dump the coal. Swiveling couplers enable the entire operation to occur while the cars are still coupled together. Unloading a unit train takes about three hours.


Shorter trains may use railcars with an "air-dump", which relies on air pressure from the engine plus a "hot shoe" on each car. This "hot shoe" when it comes into contact with a "hot rail" at the unloading trestle, shoots an electric charge through the air dump apparatus and causes the doors on the bottom of the car to open, dumping the coal through the opening in the trestle. Unloading one of these trains takes anywhere from an hour to an hour and a half. Older unloaders may still use manually operated bottom-dump rail cars and a "shaker" attached to dump the coal. Generating stations adjacent to a mine may receive coal by conveyor belt or massive diesel-electric-drive trucks.


A collier (cargo ship carrying coal) may hold 40,000 long tons of coal and takes several days to unload. Some colliers carry their own conveying equipment to unload their own bunkers; others depend on equipment at the plant. For transporting coal in calmer waters, such as rivers and lakes, flat-bottomed barges are often used. Barges are usually unpowered and must be moved by tugboats or towboats.


For start up or auxiliary purposes, the plant may use fuel oil as well. Fuel oil can be delivered to plants by pipeline, tanker, tank car or truck. Oil is stored in vertical cylindrical steel tanks with capacities as high as 90,000 barrels (14,000 m3)' worth. The heavier no. 5 "bunker" and no. 6 fuels are typically steam-heated before pumping in cold climates.



Fuel processing


Coal is prepared for use by crushing the rough coal to pieces less than 2 inches (5 cm) in size. The coal is then transported from the storage yard to in-plant storage silos by conveyor belts at rates up to 4,000 short tons per hour.


In plants that burn pulverized coal, silos feed coal to pulverizers (coal mills) that take the larger 2-inch (51 mm) pieces, grind them to the consistency of talcum powder, sort them, and mix them with primary combustion air which transports the coal to the boiler furnace and preheats the coal in order to drive off excess moisture content. A 500 MWe plant may have six such pulverizers, five of which can supply coal to the furnace at 250 tons per hour under full load.


In plants that do not burn pulverized coal, the larger 2-inch (51 mm) pieces may be directly fed into the silos which then feed either mechanical distributors that drop the coal on a traveling grate or the cyclone burners, a specific kind of combustor that can efficiently burn larger pieces of fuel.





Natural gas


Natural gas may be burned in steam boilers, gas turbines, or reciprocating engines. Sometimes coal-fired steam plants are refitted to use natural gas to reduce net carbon dioxide emissions. Oil-fuelled plants may be converted to natural gas to lower operating cost.



Dash for gas


The dash for gas occurred in the 1990s and was when 30 gas-fired power stations were built in Britain due to plentiful gas supplies from North Sea oil wells. According to the 2012 forecast by the U.S. Energy Information Administration, 27 gigawatts of capacity from coal-fired generators is to be retired from 175 US coal-fired power plants before 2016.[10] Natural gas showed a corresponding jump, increasing by a third over 2011.[11] Some coal power plants such as the 1200 MW Hearn Generating Station have stopped burning coal by switching the plant to natural gas. Coal's share of electricity generation dropped to just over 36%.[11] Natural gas accounted for 81% of new power generation in the US between 2000 and 2010.[12] Coal-fired generation puts out about twice the amount of carbon dioxide - around 2,000 pounds for every megawatt hour generated - than electricity generated by burning natural gas at 1,100 pounds of greenhouse gas per megawatt hour. As the fuel mix in the United States has changed to reduce coal and increase natural gas generation, carbon dioxide emissions have unexpectedly fallen. Carbon dioxide measured in the first quarter of 2012 was the lowest recorded of any year since 1992.[13] The list of natural gas power stations has over 100 power stations that generate between 100 MW and 5,600 MW of electricity. Natural gas plants are increasing in popularity and in 2014 generated 22% of the worlds total electricity.[14]



Oil


Heavy fuel oil was once a significant source of energy for electric power generation. After oil price increases of the 1970's, oil was displaced by coal and later natural gas. Distillate oil is still important as the fuel source for diesel engine power plants used especially in isolated communities not interconnected to a grid. Liquid fuels may also be used by gas turbine power plants, especially for peaking or emergency service. Of the three fossil fuel sources, oil has the advantages of easier transportation and handling than solid coal, and easier on-site storage than natural gas.



Combined heat and power


Combined heat and power (CHP), also known as cogeneration, is the use of a thermal power station to provide both electric power and heat (the latter being used, for example, for district heating purposes). This technology is practiced not only for domestic heating (low temperature) but also for industrial process heat, which is often high temperature heat. Calculations show that Combined Heat and Power District Heating (CHPDH) is the cheapest method in reducing (but not eliminating) carbon emissions, if conventional fossil fuels remain to be burned.[15]









Environmental impacts




The Mohave Power Station, a 1,580 MW coal power station near Laughlin, Nevada, out of service since 2005 due to environmental restrictions[16]


Thermal power plants are one of the main artificial sources of producing toxic gases and particulate matter. Fossil fuel power plants cause the emission of pollutants such as NOx, SOx, CO2, CO, PM, organic gases and polycyclic aromatic hydrocarbons.[17] World organizations and international agencies, like the IEA, are concerned about the environmental impact of burning fossil fuels, and coal in particular. The combustion of coal contributes the most to acid rain and air pollution, and has been connected with global warming. Due to the chemical composition of coal there are difficulties in removing impurities from the solid fuel prior to its combustion. Modern day coal power plants pollute less than older designs due to new "scrubber" technologies that filter the exhaust air in smoke stacks. However, emission levels of various pollutants are still on average several times greater than natural gas power plants and the scrubbers transfer the captured pollutants to wastewater, which still requires treatment in order to avoid pollution of receiving water bodies. In these modern designs, pollution from coal-fired power plants comes from the emission of gases such as carbon dioxide, nitrogen oxides, and sulfur dioxide into the air, as well a significant volume of wastewater which may contain lead, mercury, cadmium and chromium, as well as arsenic, selenium and nitrogen compounds (nitrates and nitrites).[18]


Acid rain is caused by the emission of nitrogen oxides and sulfur dioxide. These gases may be only mildly acidic themselves, yet when they react with the atmosphere, they create acidic compounds such as sulfurous acid, nitric acid and sulfuric acid which fall as rain, hence the term acid rain. In Europe and the U.S.A., stricter emission laws and decline in heavy industries have reduced the environmental hazards associated with this problem, leading to lower emissions after their peak in 1960s.
















































































































































































Carbon dioxide and other air pollution of the 9 greatest brown coal power plants in Germany (PRTR 2010)[19]
Power plant

CO2 (Tons)

NOx/NO2 (Tons)

SOx/SO2 (Tons)
Fine Dust (Tons)

Hg (kg)

Cd (kg)

Ni (kg)

Pb (kg)

As (kg)

Cr (kg)
Niederaußem
28,100,000
17,900
6,870
386
499
<10
<50
<200
49.9
<100
Jänschwalde*
23,800,000
18,700
21,400
573
592
<10
308
<200
129
<100
Weisweiler
19,900,000
12,700
3,060
456
271
<10
103
<200
67
<100
Neurath
16,900,000
11,700
3,190
251
181
<10
<50
<200
42.2
<100
Boxberg
15,100,000
10,700
7,810
167
226
<10
152
236
<20
<100
Frimmersdorf
14,400,000
9,070
5,620
257
153
<10
<50
<200
35.7
<100
Lippendorf**
12,500,000
8,570
13,800
108
1,160
68
1,960
789
21
466
Schwarze Pumpe
11,200,000
4,610
7,060
<100
243
62.9
<50
369
35.8
224
Schkopau
5,120,000
3,320
4,770
74.6
227
129
<50
<200
<20
<100
Sum without "<"
147,020,000
97,270
73,580
2,273
3,552
260
2,523
1,394
381
690
Germany total 2010[20]
834,511,385
1,328,717
444,035
211,284
9,412
4,723
105,802
193,968
6,120
55,060
Total share
18%
7.3%
17%
1.1%
38%
5.5%
2.4%
0.7%
6.2%
1.3%
* with Fuel surrogate and Waste-to-energy ** with biosolids-Waste-to-energy
















































































































































































































































Carbon dioxide and other air pollution of the 14 greatest stone coal power plants in Germany
PRTR 2010[19]
Power plant

CO2 (Tons)

NOx/NO2 (Tons)

SOx/SO2 (Tons)
Fine dust (Tons)

Hg (kg)

Cd (kg)

Ni (kg)

Pb (kg)

As (kg)

Cr (kg)
Scholven
9,390,000
7,090
4,330
244
135
31
86
<200
51
<100
Mannheim
6,510,000
3,550
1,490
148
146
<10
<50
<200
68
<100
Voerde
6,240,000
4,700
2,840
<100
38.3
<10
<50
<200
<20
<100
Staudinger*
4,480,000
2,770
665
69.9
45.6
19.1
131
<200
113
192
Heyden
3,870,000
2,920
1,380
86.7
28.4
<10
<50
<200
<20
<100
Heilbronn
3,240,000
2,160
1,660
<100
34
<10
<50
<200
<20
<100
Werne*
3,140,000
1,900
1,170
<100
11.5
<10
<50
<200
<20
<100
Wilhelmshaven
3,100,000
2,040
1,390
136
29.9
11.7
<50
<200
<20
<100
Bergkamen
3,020,000
2,100
2,040
<100
18.1
<10
<50
<200
<20
<100
Herne
2,480,000
1,790
1,340
<100
30.3
<10
<50
<200
<20
<100
Altbach**
2,220,000
1,350
906
<100
30
<10
<50
<200
<20
<100
Karlsruhe*
2,170,000
1,140
1,080
<100
19
<10
<50
<200
<20
<100
Veltheim**
1,740,000
1,290
400
52.6
10.1
22.4
<50
<200
156
<100
Bexbach
1,300,000
910
746
<100
<10
<10
<50
<200
<20
<100
Sum without "<"
52,900,000
35,710
21,437
737
576
84
217
-
388
192
Germany total 2010[20]
834,511,385
1,328,717
444,035
211,284
9,412
4,723
105,802
193,968
6,120
55,060
Share of all together
6.3%
2.7%
4.8%
0.3%
6.1%
1.8%
0.2%
-
6.3%
0.3%
* with earth gas share, ** with oil- and earth gas share

In 2008, the European Environment Agency (EEA) documented fuel-dependent emission factors based on actual emissions from power plants in the European Union.[21]



































































Pollutant Hard coal Brown coal Fuel oil Other oil Gas
CO2 (g/GJ) 94,600 101,000 77,400 74,100 56,100
SO2 (g/GJ) 765 1,361 1,350 228 0.68
NOx (g/GJ) 292 183 195 129 93.3
CO (g/GJ) 89.1 89.1 15.7 15.7 14.5
Non methane organic compounds (g/GJ) 4.92 7.78 3.70 3.24 1.58
Particulate matter (g/GJ) 1,203 3,254 16 1.91 0.1
Flue gas volume total (m3/GJ) 360 444 279 276 272


Carbon dioxide






Taichung coal-fired power plant in Taiwan, the world's largest carbon dioxide emitter[22]


Electricity generation using carbon-based fuels is responsible for a large fraction of carbon dioxide (CO2) emissions worldwide and for 34% of U.S. man-made carbon dioxide emissions in 2010. In the U.S. 70% of electricity is generated by combustion of fossil fuels.[23]


Coal contains more carbon than oil or natural gas fossil fuels, resulting in greater volumes of carbon dioxide emissions per unit of electricity generated. In 2010, coal contributed about 81% of CO2 emissions from generation and contributed about 45% of the electricity generated in the United States.[24] In 2000, the carbon intensity (CO2 emissions) of U.S. coal thermal combustion was 2249 lbs/MWh (1,029 kg/MWh)[25] while the carbon intensity of U.S. oil thermal generation was 1672 lb/MWh (758 kg/MWh or 211 kg/GJ)[26] and the carbon intensity of U.S. natural gas thermal production was 1135 lb/MWh (515 kg/MWh or 143 kg/GJ).[27]


The Intergovernmental Panel on Climate Change (IPCC) reports that increased quantities of the greenhouse gas carbon dioxide within the atmosphere will "very likely" lead to higher average temperatures on a global scale (global warming). Concerns regarding the potential for such warming to change the global climate prompted IPCC recommendations calling for large cuts to CO2 emissions worldwide.[28]


Emissions can be reduced with higher combustion temperatures, yielding more efficient production of electricity within the cycle. Carbon capture and storage (CCS) of emissions from coal-fired power stations is another alternative but the technology is still being developed and will increase the cost of fossil fuel-based production of electricity. CCS may not be economically viable, unless the price of emitting CO2 to the atmosphere rises.



Estimation of carbon dioxide emissions


The CO2 emissions from a fossil fuel power station can be estimated with the following formula:


CO2 emissions = capacity x capacity factor x heat rate x emission intensity x time


where "capacity" is the "nameplate capacity" or the maximum allowed output of the plant, "capacity factor" or "load factor" is a measure of the amount of power that a plant produces compared with the amount it would produce if operated at its rated capacity nonstop, heat rate is thermal energy in/electrical energy out, emission intensity (also called emission factor) is the CO2 emitted per unit of heat generated for a particular fuel.


As an example, a new 1500 MW supercritical lignite-fueled power station running on average at half its capacity might have annual CO2 emissions estimated as:


= 1500MW x 0.5 x 100/40 x 101000kg/TJ x 1year


= 1500MJ/s x 0.5 x 2.5 x 0.101 kg/MJ x 365x24x60x60s


= 1.5x103 x 5x10-1 x 2.5 x 1.01-1 x 3.1536x107 kg


= 59.7 x103-1-1+7 kg


= 5.97 Mt


Thus the example power station is estimated to emit about 6 megatonnes of carbon dioxide each year.
The results of similar estimations are mapped by organisations such as Coalswarm, CarbonTracker and ElectricityMap.



Particulate matter


Another problem related to coal combustion is the emission of particulates that have a serious impact on public health. Power plants remove particulate from the flue gas with the use of a bag house or electrostatic precipitator. Several newer plants that burn coal use a different process, Integrated Gasification Combined Cycle in which synthesis gas is made out of a reaction between coal and water. The synthesis gas is processed to remove most pollutants and then used initially to power gas turbines. Then the hot exhaust gases from the gas turbines are used to generate steam to power a steam turbine. The pollution levels of such plants are drastically lower than those of "classic" coal power plants.[29]


Particulate matter from coal-fired plants can be harmful and have negative health impacts. Studies have shown that exposure to particulate matter is related to an increase of respiratory and cardiac mortality.[30] Particulate matter can irritate small airways in the lungs, which can lead to increased problems with asthma, chronic bronchitis, airway obstruction, and gas exchange.[30]


There are different types of particulate matter, depending on the chemical composition and size. The dominant form of particulate matter from coal-fired plants is coal fly ash, but secondary sulfate and nitrate also comprise a major portion of the particulate matter from coal-fired plants.[31] Coal fly ash is what remains after the coal has been combusted, so it consists of the incombustible materials that are found in the coal.[32]


The size and chemical composition of these particles affects the impacts on human health.[30][31] Currently coarse (diameter greater than 2.5 μm) and fine (diameter between 0.1 μm and 2.5 μm) particles are regulated, but ultrafine particles (diameter less than 0.1 μm) are currently unregulated, yet they pose many dangers.[30] Unfortunately much is still unknown as to which kinds of particulate matter pose the most harm, which makes it difficult to come up with adequate legislation for regulating particulate matter.[31]


There are several methods of helping to reduce the particulate matter emissions from coal-fired plants. Roughly 80% of the ash falls into an ash hopper, but the rest of the ash then gets carried into the atmosphere to become coal-fly ash.[32] Methods of reducing these emissions of particulate matter include:



  1. a baghouse

  2. an electrostatic precipitator (ESP)

  3. cyclone collector


The baghouse has a fine filter that collects the ash particles, electrostatic precipitators use an electric field to trap ash particles on high-voltage plates, and cyclone collectors use centrifugal force to trap particles to the walls.[32] A recent study indicates that sulfur emissions from fossil fueled power stations in China may have caused a 10-year lull in global warming (1998-2008).[33]



Wastewater


Fossil-fuel power stations, particularly coal-fired plants, are a major source of industrial wastewater. Wastewater streams include flue-gas desulfurization, fly ash, bottom ash and flue gas mercury control. Plants with air pollution controls such as wet scrubbers typically transfer the captured pollutants to the wastewater stream.[18]


Ash ponds, a type of surface impoundment, are a widely used treatment technology at coal-fired plants. These ponds use gravity to settle out large particulates (measured as total suspended solids) from power plant wastewater. This technology does not treat dissolved pollutants. Power stations use additional technologies to control pollutants, depending on the particular wastestream in the plant. These include dry ash handling, closed-loop ash recycling, chemical precipitation, biological treatment (such as an activated sludge process), membrane systems, and evaporation-crystallization systems.[18] Technological advancements in ion exchange membranes and electrodialysis systems has enabled high efficiency treatment of flue-gas desulfurization wastewater to meet recent EPA discharge limits.[34]



Radioactive trace elements


Coal is a sedimentary rock formed primarily from accumulated plant matter, and it includes many inorganic minerals and elements which were deposited along with organic material during its formation. As the rest of the Earth's crust, coal also contains low levels of uranium, thorium, and other naturally occurring radioactive isotopes whose release into the environment leads to radioactive contamination. While these substances are present as very small trace impurities, enough coal is burned that significant amounts of these substances are released. A 1,000 MW coal-burning power plant could have an uncontrolled release of as much as 5.2 metric tons per year of uranium (containing 74 pounds (34 kg) of uranium-235) and 12.8 metric tons per year of thorium.[35] In comparison, a 1,000 MW nuclear plant will generate about 30 metric tons of high-level radioactive solid packed waste per year.[36] It is estimated that during 1982, US coal burning released 155 times as much uncontrolled radioactivity into the atmosphere as the Three Mile Island incident.[37] The collective radioactivity resulting from all coal burning worldwide between 1937 and 2040 is estimated to be 2,700,000 curies or 0.101 EBq.[35] During normal operation, the effective dose equivalent from coal plants is 100 times that from nuclear plants.[35] Normal operation however, is a deceiving baseline for comparison: just the Chernobyl nuclear disaster released, in iodine-131 alone, an estimated 1.76 EBq.[38] of radioactivity, a value one order of magnitude above this value for total emissions from all coal burned within a century, while the iodine-131, the major radioactive substance which comes out in accident situations, has a half life of just 8 days.



Water and air contamination by coal ash


A study released in August 2010 that examined state pollution data in the United States by the organizations Environmental Integrity Project, the Sierra Club and Earthjustice found that coal ash produced by coal-fired power plants dumped at sites across 21 U.S. states has contaminated ground water with toxic elements. The contaminants including the poisons arsenic and lead.[39]


Arsenic has been shown to cause skin cancer, bladder cancer and lung cancer, and lead damages the nervous system.[40] Coal ash contaminants are also linked to respiratory diseases and other health and developmental problems, and have disrupted local aquatic life.[39] Coal ash also releases a variety of toxic contaminants into nearby air, posing a health threat to those who breath in fugitive coal dust.
[40]


Currently, the EPA does not regulate the disposal of coal ash; regulation is up to the states and the electric power industry has been lobbying to maintain this status quo. Most states require no monitoring of drinking water near coal ash dump sites. The study found an additional 39 contaminated U.S. sites and concluded that the problem of coal ash-caused water contamination is even more extensive in the United States than has been estimated. The study brought to 137 the number of ground water sites across the United States that are contaminated by power plant-produced coal ash.[39]



Mercury contamination



U.S. government scientists tested fish in 291 streams around the country for mercury contamination. They found mercury in every fish tested, according to the study by the U.S. Department of the Interior. They found mercury even in fish of isolated rural waterways. Twenty five percent of the fish tested had mercury levels above the safety levels determined by the U.S. Environmental Protection Agency for people who eat the fish regularly. The largest source of mercury contamination in the United States is coal-fueled power plant emissions.[41]



Greening of fossil fuel power plants




Several methods exist to improve the efficiency of fossil fuel power plants. A frequently used and cost-efficient method is to convert a plant to run on a different fuel. This includes conversions of coal power plants to biomass or waste[42][43][44] and conversions of natural gas power plants to biogas. Conversions of coal powered power plants to waste-fired power plants have an extra benefit in that they can reduce landfilling. In addition, waste-fired power plants can be equipped with material recovery, which is also beneficial to the environment. In some instances, torrefaction of biomass may be needed if biomass is the material the converted fossil fuel power plant will be using.[45]


Improving energy efficiency of a coal-fired power plant also reduces emissions. For example, emissions can be reduced by upgrading existing plants or building new high-efficiency, low-emissions plants. Such plants emit almost 20% less CO2 than a subcritical unit operating at a similar load. Over the longer term, HELE plants can further facilitate emission reductions because coal-fired plants operating at the highest efficiencies are also the most appropriate option for carbon capture and storage retrofit.[46]


Regardless of the conversion, a truly low-carbon fossil fuel power plant implements carbon capture and storage, which means that the exhaust CO2 is not released into the environment and the fossil fuel power plant becomes an emissionless power plant. A 2006 example of a carbon capture and storage fossil fuel power plant is the pilot Elsam power station near Esbjerg, Denmark.[47]



Coal Pollution Mitigation


Coal Pollution Mitigation is a process whereby coal is chemically washed of minerals and impurities, sometimes gasified, burned and the resulting flue gases treated with steam, with the purpose of removing sulfur dioxide, and reburned so as to make the carbon dioxide in the flue gas economically recoverable, and storable underground (the latter of which is called "carbon capture and storage"). The coal industry uses the term "clean coal" to describe technologies designed to enhance both the efficiency and the environmental acceptability of coal extraction, preparation and use,[48] but has provided no specific quantitative limits on any emissions, particularly carbon dioxide. Whereas contaminants like sulfur or mercury can be removed from coal, carbon cannot be effectively removed while still leaving a usable fuel, and clean coal plants without carbon sequestration and storage do not significantly reduce carbon dioxide emissions. James Hansen in an open letter to U.S. President Barack Obama has advocated a "moratorium and phase-out of coal plants that do not capture and store CO2". In his book Storms of My Grandchildren, similarly, Hansen discusses his Declaration of Stewardship the first principle of which requires "a moratorium on coal-fired power plants that do not capture and sequester carbon dioxide".[49]



Clean gas


Gas-fired power plants can also be modified to run on hydrogen, the latter of which can be created on-site from natural gas.[50] Since 2013, the conversion process has been improved by scientists at Karlsruhe Liquid-metal Laboratory (KALLA) as they succeeded in allowing the soot to be easily removed (soot is a byproduct of the process and damaged the working parts in the past -most notably the nickel-iron-cobaltcatalyst-).[51][52] The soot (which contains the carbon) can then be stored underground and is not released into the atmosphere.



Alternatives to fossil fuel power plants




U.S. 2014 Electricity Generation By Type.[53]


Alternatives to fossil fuel power plants include nuclear power, solar power, geothermal power, wind power, hydropower, biomass power plants and other renewable energies (see non-carbon economy). Some of these are proven technologies on an industrial scale (i.e. nuclear, wind, tidal, hydroelectric and biomass fired power) others are still in prototype form.


Nuclear power, and geothermal power may be classed as heat pollutants as they add heat energy to the biosphere that would not otherwise be released.[citation needed] The net quantity of energy conversion within the biosphere due to the utilisation of wind power, solar power, tidal power, hydroelectric power (hydroelectricity) is static and is derived from the effects of sunlight and the movement of the moon and planets.


Generally, the cost of electrical energy produced by non fossil fuel burning power plants is greater than that produced by burning fossil fuels. This statement however only includes the cost to produce the electrical energy and does not take into account indirect costs associated with the many pollutants created by burning fossil fuels (e.g. increased hospital admissions due to respiratory diseases caused by fine smoke particles).



Relative cost by generation source



When comparing power plant costs, it is customary to start by calculating the cost of power at the generator terminals by considering several main factors. External costs such as connections costs, the effect of each plant on the distribution grid are considered separately as an additional cost to the calculated power cost at the terminals.


Initial factors considered are:



  • Capital costs, including waste disposal and decommissioning costs for nuclear energy.

  • Operating and maintenance costs.

  • Fuel costs for fossil fuel and biomass sources, and which may be negative for wastes.

  • Likely annual hours per year run or load factor, which may be as low as 30% for wind energy, or as high as 90% for nuclear energy.

  • Offset sales of heat, for example in combined heat and power district heating (CHP/DH).


These costs occur over the 30–50 year life of the fossil fuel power plants, using discounted cash flows. In general large fossil plants are attractive due to their low initial capital costs—typically around £750–£1000 per kilowatt electrical compared to perhaps £1500 per kilowatt for onshore wind.[citation needed]



See also




  • Biomass

  • Boiler (power generation)

  • Coal analyzer

  • Coal mining

  • Coal power in the United States

  • Combined heat and power

  • Cooling tower system

  • Environmental impact of the coal industry

  • Flue gas stacks

  • Fossil fuel phase-out

  • Geothermal power

  • Global warming

  • Greenhouse gas

  • List of coal power stations

  • List of thermal power station failures

  • Mercury vapor turbine

  • Natural gas

  • Power station

  • Relative cost of electricity generated by different sources

  • Renewable energy power station

  • Steam reforming

  • Steam turbine

  • Thermal power station

  • Water-tube boiler




References





  1. ^ "Key World Energy Statistics (2018)" (PDF). International Energy Agency. 2018. p. 14..mw-parser-output cite.citation{font-style:inherit}.mw-parser-output .citation q{quotes:"""""""'""'"}.mw-parser-output .citation .cs1-lock-free a{background:url("//upload.wikimedia.org/wikipedia/commons/thumb/6/65/Lock-green.svg/9px-Lock-green.svg.png")no-repeat;background-position:right .1em center}.mw-parser-output .citation .cs1-lock-limited a,.mw-parser-output .citation .cs1-lock-registration a{background:url("//upload.wikimedia.org/wikipedia/commons/thumb/d/d6/Lock-gray-alt-2.svg/9px-Lock-gray-alt-2.svg.png")no-repeat;background-position:right .1em center}.mw-parser-output .citation .cs1-lock-subscription a{background:url("//upload.wikimedia.org/wikipedia/commons/thumb/a/aa/Lock-red-alt-2.svg/9px-Lock-red-alt-2.svg.png")no-repeat;background-position:right .1em center}.mw-parser-output .cs1-subscription,.mw-parser-output .cs1-registration{color:#555}.mw-parser-output .cs1-subscription span,.mw-parser-output .cs1-registration span{border-bottom:1px dotted;cursor:help}.mw-parser-output .cs1-ws-icon a{background:url("//upload.wikimedia.org/wikipedia/commons/thumb/4/4c/Wikisource-logo.svg/12px-Wikisource-logo.svg.png")no-repeat;background-position:right .1em center}.mw-parser-output code.cs1-code{color:inherit;background:inherit;border:inherit;padding:inherit}.mw-parser-output .cs1-hidden-error{display:none;font-size:100%}.mw-parser-output .cs1-visible-error{font-size:100%}.mw-parser-output .cs1-maint{display:none;color:#33aa33;margin-left:0.3em}.mw-parser-output .cs1-subscription,.mw-parser-output .cs1-registration,.mw-parser-output .cs1-format{font-size:95%}.mw-parser-output .cs1-kern-left,.mw-parser-output .cs1-kern-wl-left{padding-left:0.2em}.mw-parser-output .cs1-kern-right,.mw-parser-output .cs1-kern-wl-right{padding-right:0.2em}


  2. ^ Charles Camp; Department of Civil Engineering. "PCA Manual" (PDF). University of Memphis, Herff College of Civil Engineering. Retrieved 8 January 2013.


  3. ^ Heidari, N.; Pearce, J. M. (2016). "A Review of Greenhouse Gas Emission Liabilities as the Value of Renewable Energy for Mitigating Lawsuits for Climate Change Related Damages". Renewable and Sustainable Energy Reviews. 55: 899–908. doi:10.1016/j.rser.2015.11.025.


  4. ^ Sonal Patel (4 January 2017). "Who Has the World's Most Efficient Coal Power Plant Fleet?". Retrieved 5 September 2018.


  5. ^
    "Electric Generation Efficiency: Working Document of the NPC Global Oil & Gas Study" (PDF). National Petroleum Council. 18 July 2007. p. 5. Archived from the original (PDF) on 2010-07-04. Retrieved 18 July 2007.



  6. ^ GE Power’s H Series Turbine Archived 11 November 2007 at the Wayback Machine


  7. ^ Trivelpiece, Alvin (1993). "The Future of Nuclear Research Centers" (PDF). Oak Ridge National Laboratory Review. 26 (3 & 4): 28.


  8. ^ Avedøre Power Station Archived 25 February 2012 at the Wayback Machine from the web page of DONG Energy


  9. ^ Energy Information Administration


  10. ^ Gerhardt, Tina (1 November 2012). "Record Number of Coal Power Plants Retire". E-Magazine. Archived from the original on 1 November 2012.


  11. ^ ab Electric Power Monthly, March 2011 (released May 2012), U.S. Energy Information Administration


  12. ^ Most electric generating capacity additions in the last decade were natural gas-fired - Today in Energy - U.S. Energy Information Administration (EIA)


  13. ^ Nuwer, Rachel (August 17, 2012). "A 20-Year Low in U.S. Carbon Emissions".


  14. ^ 2014 Key World Energy Statistics (PDF) (Report). International Energy Agency. p. 24. Archived from the original (PDF) on 2014-10-21.


  15. ^ Claverton-energy.co.uk


  16. ^ SEC Mohave Generation Station Archived 14 September 2008 at the Wayback Machine Retrieved 24-07-2008


  17. ^ Fouladi Fard, Reza; Naddafi, K.; Yunesian, M.; Nabizadeh Nodehi, R.; et al. (2016). "The assessment of health impacts and external costs of natural gas-fired power plant of Qom". Environmental Science and Pollution Research. 23 (20): 20922–20936. doi:10.1007/s11356-016-7258-0. PMID 27488708.


  18. ^ abc "Effluent Limitations Guidelines and Standards for the Steam Electric Power Generating Point Source Category". Washington, DC: US Environmental Protection Agency (US EPA). 2015-09-30.


  19. ^ ab PRTR - Europäisches Emissionsregister


  20. ^ ab Emissionsentwicklung 1990 - 2011, klassische Luftschadstoffe, Schwermetalle Nationale Trendtabellen für die deutsche Berichterstattung atmosphärischer Emissionen seit 1990, Umweltbundesamt (Excel-Tabelle), 2013


  21. ^
    Air pollution from electricity-generating large combustion plants (PDF), Copenhagen: European Environment Agency (EEA), 2008, ISBN 978-92-9167-355-1



  22. ^ The Phoenix Sun | Dirty numbers | The 200 Most Polluting Power Plants in the World


  23. ^ "Sources Climate Change". US EPA. 2012. Retrieved August 26, 2012.


  24. ^ "Electricity Sector Emissions Climate Change". US EPA. 2012. Retrieved August 26, 2012.


  25. ^ US EPA Clean Energy—Coal


  26. ^ US EPA Clean Energy—Oil


  27. ^ US EPA Clean Energy—Gas


  28. ^ Solomon, S.; et al. (2007). "Summary for policymakers" (PDF). A report of Working Group I of the Intergovernmental Panel on Climate Change. IPCC. Retrieved 24 March 2010.


  29. ^ Committee on Benefits of DOE R&D on Energy Efficiency and Fossil Energy, US NRC (2001). Energy research at DOE: was it worth it? Energy efficiency and fossil energy research 1978 to 2000. National Academies Press. p. 174. ISBN 978-0-309-07448-3.


  30. ^ abcd Nel, A. (2005, May 6). Air Pollution-Related Illness: Effects of Particles. Science, 308(5723), 804-806.


  31. ^ abc Grahame, T., & Schlesinger, R. (2007, April 15). Health Effects of Airborne Particulate Matter: Do We Know Enough to Consider Regulating Specific Particle Types or Sources?. Inhalation Toxicology, 19(6–7), 457–481.


  32. ^ abc Schobert, H. H. (2002). Energy and Society. New York: Taylor & Francis, 241–255.


  33. ^ Freedman, Andrew (July 5, 2011). "New study blames 10-year lull in global warming on China coal use, air pollution". Washington Post. Retrieved 2018-10-29.


  34. ^ "Lowering Cost and Waste in Flue Gas Desulfurization Wastewater Treatment". Power Mag. Electric Power. March 2017. Retrieved 6 April 2017.


  35. ^ abc Coal Combustion: Nuclear Resource or Danger? Archived 5 February 2007 at the Wayback Machine by Alex Gabbard, ORNL Review, Summer/Fall 1993, Vol. 26, Nos. 3 and 4.


  36. ^ Thompson, Linda. "Vitrification of Nuclear Waste". PH240 - Fall 2010: Introduction to the Physics of Energy. Stanford University. Retrieved 10 August 2014.


  37. ^ Physics.ohio-state.edu Archived 27 March 2009 at the Wayback Machine


  38. ^ "Fukushima radioactive fallout nears Chernobyl levels". Newscientist.com. Retrieved 24 April 2011.


  39. ^ abc "Study of Coal Ash Sites Finds Extensive Water Contamination" McClatchy; also archived at: commondreams.org


  40. ^ ab EarthJustice news release, 2010 Sept. 16, "New Report—Coal Ash Linked To Cancer and Other Maladies; Coal's Waste Is Poisoning Communities in 34 States" Archived 19 September 2010 at the Wayback Machine Earthjustice.org and Physicians for Social Responsibility, "Coal Ash: The Toxic Threat to Our Communities and Our Environment" 2010 September 16, earthjustice.org


  41. ^ nytimes.com "Mercury Found in Every Fish Tested, Scientists Say" New York Times, 2009 Aug. 19


  42. ^ Coal to biomass power plant conversion


  43. ^ Coal to biomass conversion by Georgia Power


  44. ^ Conversion of coal to waste-fired power plant Archived 21 July 2009 at the Wayback Machine


  45. ^ Torrefaction of biomass sometimes needed when using biomass in converted FFPS


  46. ^ Barnes, Ian (March 2015). "Upgrading the Efficiency of the World's Coal Fleet to Reduce CO2 Emissions". Cornerstone.


  47. ^ ENS (March 15, 2006). "Europe Tests Carbon Capture at Coal-Fired Power Plant". Environment News Service. Retrieved 15 July 2012.


  48. ^ AustralianCoal.com.au Archived 7 December 2007 at the Wayback Machine—Clean Coal Overview


  49. ^ Hansen, James (2009). Storms of My Grandchildren. London: Bloomsbury Publishing. p. 242. ISBN 978-1-4088-0745-3.


  50. ^ Natural gas to hydrogen: Natural gas reforming


  51. ^ The reaction that would give us clean fossil fuels forever


  52. ^ Hydrogen from methane without CO2 emissions


  53. ^ EIA - Electricity Data




Bibliography




  • Steam: Its Generation and Use (2005). 41st edition, Babcock & Wilcox Company,
    ISBN 0-9634570-0-4


  • Steam Plant Operation (2011). 9th edition, Everett B. Woodruff, Herbert B. Lammers, Thomas F. Lammers (coauthors), McGraw-Hill Professional,
    ISBN 978-0-07-166796-8


  • Power Generation Handbook: Fundamentals of Low-Emission, High-Efficiency Power Plant Operation (2012). 2nd edition. Philip Kiameh, McGraw-Hill Professional,
    ISBN 978-0-07-177227-3


  • Standard Handbook of Powerplant Engineering (1997). 2nd edition, Thomas C. Elliott, Kao Chen, Robert Swanekamp (coauthors), McGraw-Hill Professional,
    ISBN 0-07-019435-1



External links







  • Conventional coal-fired power plant


  • "Power plant diagram". tva.gov. Tennessee Valley Authority.

  • Large industrial cooling towers

  • Statistics on existing U.S. coal-fired plants

  • Coal Power more deadly than Nuclear


  • "Must We Suffer Smoke" , May 1949, Popular Science article on early methods of scrubbing emissions from coal-fired power plants

  • The Future of Coal: Utilizing America’s Abundant Energy Resources: Hearing before the Subcommittee on Energy, Committee on Science, Space, and Technology, House of Representatives, One Hundred Thirteenth Congress, First Session, July 25, 2013


  • U.S. President Obama threatens bankruptcy to anyone building a coal-fired power plant in the U.S. 2008 interview with San Francisco Gate

  • Gas Power Plant News from Power Engineering Magazine










Popular posts from this blog

Lambaréné

維納斯堡 (華盛頓州)

Mononymous person